3. '''Clamp the workpieces together and place between the Electrode Tips.'''
3. '''Clamp the workpieces together and place between the Electrode Tips.'''
{| class="infobox" cellspacing="5" style="width: 22em; text-align: left; font-size: 100%; line-height: 1.5em;"
! colspan="2" class="infobox-image" | [[File:Metal_shop_spot_welder_tong_adj.png|300px|Spot welder tong adj ]]
|-
| colspan="2" |  Tong Adjustment Screws are Locaeted on the Top and the Bottom.
|-
|}


* Ensure good contact between metal pieces to be welded. Gaps weaken welds.
* Ensure good contact between metal pieces to be welded. Gaps weaken welds.
Line 104: Line 111:


4. Steady the workpiece and press down on the Operating Lever to close the Tongs.
4. Steady the workpiece and press down on the Operating Lever to close the Tongs.
{| class="infobox" cellspacing="5" style="width: 22em; text-align: left; font-size: 100%; line-height: 1.5em;"
! colspan="2" class="infobox-image" | [[File:Metal_shop_spot_welder_tong_adj.png|300px|Spot welder w labels ]]
|-
| colspan="2" |  Tong Adjustment Screws are Locaeted on the Top and the Bottom.
|-
|}


5. '''To weld, push the Power Switch sideways in either direction, then release.'''
5. '''To weld, push the Power Switch sideways in either direction, then release.'''
Line 121: Line 121:


{| class="infobox" cellspacing="5" style="width: 22em; text-align: left; font-size: 100%; line-height: 1.5em;"
{| class="infobox" cellspacing="5" style="width: 22em; text-align: left; font-size: 100%; line-height: 1.5em;"
! colspan="2" class="infobox-image" | [[File:Metal_shop_spot_welder_electrode_tip_alignment.png|250px|Spot welder w labels ]]
! colspan="2" class="infobox-image" | [[File:Metal_shop_spot_welder_electrode_tip_alignment.png|250px|Spot electrode alignment ]]
|-
|-
| colspan="2" |  Tong Adjustment Screws are Locaeted on the Top and the Bottom.
| colspan="2" |  Alignment of the Electrodes in the Spot Welder
|-
|-
|}
|}
Line 144: Line 144:


{| class="infobox" cellspacing="5" style="width: 22em; text-align: left; font-size: 100%; line-height: 1.5em;"
{| class="infobox" cellspacing="5" style="width: 22em; text-align: left; font-size: 100%; line-height: 1.5em;"
! colspan="2" class="infobox-image" | [[File:Metal_shop_spot_welder_good_v_bad_electrode_tip.png|250px|Spot welder w labels ]]
! colspan="2" class="infobox-image" | [[File:Metal_shop_spot_welder_good_v_bad_electrode_tip.png|250px|Good v bad electrodes ]]
|-
|-
| colspan="2" |  Tong Adjustment Screws are Locaeted on the Top and the Bottom.
| colspan="2" |  A new electrode compared with a worn electrode
|-
|-
|}
|}

Revision as of 14:38, 5 February 2024



Chicago Spot Welders
Spot Welder
General Info
Make Various
Model n/a
Serial Unknown
Specs n/a
Manual n/a
Asylum Info
Location Metal Shop
Rubric n/a
Training Tool classes
Testing Tool testing, or [[:Category:Metal Shop#Tool

Testing Night|come to the shop on Tool Testing Night]]

Restrictions green


Use for:

  • Sheet metal, including uncoated mild steel, galvanized steel, and stainless.
  • Mild Steel Capacity: up to 3/16” combined thickness.
  • Galvanized Steel Capacity: two pieces 16 ga (0.059”).

Do Not Use for:

  • Aluminum, copper or copper alloys.
  • Note that spot welds are weak, typically for ornamental applications.

Safety Hazards

height: 1.5em;"
Goggles.png

1. Sparks from the welding process. Eye Protection Required.

2. Electrocution, causing potential injury or death.

3. Burns from flame, sparks, hot workpieces. Wear protective clothing and shoes, leather gloves.

4. Poisoning from breathing gases produced by the welding process. Use proper ventilation. Do not stick head in fumes. Respirator recommended.

5. Keep workplace clear of flammable materials, including grease, oil, solvents, paper.

Operation Notes

height: 1.5em;"
50% duty.png
  • Avoid Electric Shock.
  • Never touch the Upper and Lower Tongs when unit plugged in.
  • Never touch Electrode Tips to grounded material when unit is plugged in.
  • Never expose unit to water or damp objects, especially during use.
  • Metal workpiece must be clean. Remove rust, scale, oxides, paint, grease, and oil.
  • Welder has a 50% duty cycle. Unit can weld for 5 seconds out of each 10 second time interval without overheating. Failure to observe duty cycle can destroy the welder.
  • 'Excessive Tong pressure can damage the Electrode Tips. Do not use the Tongs as a clamp or vise. Use separate clamps to hold workpieces together for good contact at the weld point.
  • The Electrode Tips deform during use and occasionally need dressing. For optimal weld quality, inspect Electrode Tips before use and clean, dress (resurface), or replace as needed for proper contact surface.
  • For successful welds, do not weld more than two pieces of metal at a time.


Warning Safety glasses Eye protection required!


Spot welder w labels
Parts of the Spot Welder

Basic Operating Instructions

1. Perform a safety check.

  • Are the Electrode Tips in good condition?
  • Do the Electrode Tips align?
  • Check if the Tong Pressure is appropriate for your workpiece. Adjust as needed.
  • Prevent unintentional starting. Ensure the power switch is in the off-position before connecting to power source or moving the welder.
  • Check for loose, cracked or broken parts.
  • Do not use if the cord is damaged.

2. Clean the work pieces. Remove scale, dross, paint, grease, oil.

3. Clamp the workpieces together and place between the Electrode Tips.

Spot welder tong adj
Tong Adjustment Screws are Locaeted on the Top and the Bottom.
  • Ensure good contact between metal pieces to be welded. Gaps weaken welds.
  • Do not use the Tongs or Electrode Tips as a clamp.
  • The Workpiece and Tongs will get very hot. DO NOT place hands on the workpiece for the weld. Hold the clamp when welding.

4. Steady the workpiece and press down on the Operating Lever to close the Tongs.

5. To weld, push the Power Switch sideways in either direction, then release.

The Power Switch provides quick application of electric current, allowing precise control of the weld time. Weld time is determined by the thickness of the workpieces, the metal type, and the skill of the operator.

6. Raise the Operating Lever to open the Tongs to release the workpiece. Allow the Electrode Tips and the workpiece to cool before handling.

Tong and Electrode Tip Adjustment

Spot electrode alignment
Alignment of the Electrodes in the Spot Welder

Correct Tong / Electrode Tip alignment is necessary to create a proper weld.

Check the following:

  • Are the Tongs or Electrode Tips aligned?

Adjust the Tongs. To adjust, loosen the appropriate screw, more the Tong and re-tighten.

Electrode Tip Condition

  • Inspect the Electrode Tips and clean, dress (resurface), or replace as needed to maintain a proper contact surface.
  • Use a file or tip dresser tool to dress Electrode Tips. Restore the spot diameter and face angle to a condition approximately the same as a new tip.

Tong Pressure

Good v bad electrodes
A new electrode compared with a worn electrode

Correct Tong pressure is needed for a proper weld and to prevent damage to the Electrode Tips.

1. If the Tong pressure is too weak and the workpieces are loose when the Tongs close, severe arcing will occur between the workpieces when current is applied. No weld will be produced.

  • To increase the Tong pressure, loosen the Front Jam Nut. Loosening the Front Jam Nut increases the pressure.
  • Tighten the Rear Jam Nut toward the Upper Tong Holder to lock the adjustment.

2. If the Tong pressure is too strong, the weld nugget will dimple, and molten material will be forced out around the weld point.

  • To decrease the Tong pressure, loosen the REAR Jam Nut and adjust the Front Jam Nut. Tighten the Rear Jam Nut to lock the position.

3. Adjust Cap Screw at the rear of the Fixed Handle to determine how firmly the Tongs apply pressure to the workpiece. Turn the Cap Screw down to increase closing depth of the Operating Lever, increasing pressure. Make sure the Operating lever can be easily raised once the weld is complete.

4. The pressure required to push down the Operating Lever may be adjusted by turning the Hex Nuts located on each side of the Front Housing clockwise or counterclockwise to loosen or tighten the Lever action.