Plasma Torch parameters Data Tables

From Artisans Asylum Wiki

45A Shielded Mild Steel Imperial Units

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
in in seconds ipm Volts ipm Volts
26GA 0.15 0.24 0.2 350 133 500 128
22GA 0.15 0.24 0.2 350 133 450 128
18GA 0.15 0.24 0.3 350 134 400 128
16GA 0.15 0.24 0.3 350 135 400 129
14GA 0.15 0.24 0.4 270 135 320 129
12GA 0.15 0.24 0.6 190 138 216 131
10GA 0.15 0.24 0.6 100 139 164 131
3/16 in 0.15 0.24 0.7 70 140 108 132
1/4 in 0.15 0.24 0.8 48 140? 73 132
3/8 in 0.15 0.24
1/2 in 0.15 0.24
5/8 in 0.15 0.24
3/4 in 0.15 0.24
7/8 in 0.15 0.24
1 in 0.15 0.24
1-1/8 in 0.15 0.24
1-1/4 in 0.15 0.24

Fine Cut Shielded Mild Steel Imperial Units

Material

Thickness

Amps Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings
Cut Speed Voltage
A in in seconds ipm Volts
26GA 40 0.15 0.24 0.2 325 78
24GA 40 0.15 0.24 0.2 325 78
22GA 40 0.15 0.24 0.3 325 78
20GA 40 0.15 0.24 0.3 325 78
18GA 45 0.15 0.24 0.4 325 78
16GA 45 0.15 0.24 0.4 250 78
14GA 45 0.15 0.24 0.4 200 78
12GA 45 0.15 0.24 0.5 120 78
10GA 45 0.15 0.24 0.5 95 78