Antwerp Shop Air: Difference between revisions
No edit summary |
No edit summary |
||
Line 82: | Line 82: | ||
The most frequent problem is caused by opening the ball valves ''after'' the compressor has been started. The pressure transient will throw an error in the machine controller, and it will stop running. | The most frequent problem is caused by opening the ball valves ''after'' the compressor has been started. The pressure transient will throw an error in the machine controller, and it will stop running. | ||
To clear the error, | To clear the error, press the button with the ([[File:Antwerp_compressor_error_clear_icon.png|32px]]) symbol. |
Revision as of 13:06, 15 October 2024
Kaiser Air Compressor | |
---|---|
General Info | |
Make | Kaiser |
Model | |
Serial | |
Specs | n/a |
Manual | |
Asylum Info | |
Location | Antwerp East Entry |
Rubric | n/a |
Training | |
Testing | |
Restrictions | green |
Description
This is a screw-type air compressor that is sized for the whole building. Presently it is only connected to the Metal Shop and the Machine Shop. Branches in the Metal Shop supply feed the Plasma Shop, the Sand Blaster, and the Powder Coating Facility. Supply pressure is about 100 psi. It has an automatic desiccator between the compressor and accumulator.
There is a copper manifold that spans the whole building, but it needs troubleshooting. Until this is done, connections are made ad-hoc and the compressor is only turned on when it is needed.
How To Turn It On
These three valves must be OPEN to use the compressor. |
The compressor closet is located in the Antwerp loading dock entry, between the emergency exit and the utility closet. |
1. Find the closet. The light switch is inside, to the left of the door.
2. Don some hearing protection. The next step is LOUD
3. Open the three ball valves that control the air supply. Expect a loud "WHOOOSH." Two other valves are clearly labeled NOT to change.
Press the GREEN button to start. |
Note: To open a ball valve turn the handle so it is parallel to the pipe passing through it.
4. Walk around the right side of the compressor unit and find the "front" panel.
5. Press the green "ON" button to start the compressor.
6. Allow a few minutes for the air pressure to reach its control level.
How To Turn It Off
If you were the one who turned the machine on, then you should turn it off when you are finished, unless there are other users.
If there are other users, inform them before you leave that they are responsible for shutting off the air compressor.
Press the RED button to stop. |
1. Close the three ball valves illustrated above.
2. Go around the machine and press the red "OFF" button.
3. Close the door and turn off the light.
Troubleshooting
The most frequent problem is caused by opening the ball valves after the compressor has been started. The pressure transient will throw an error in the machine controller, and it will stop running.